<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
		>
<channel>
	<title>Comments on: How do you currently choose where to place equipment in your data centre?</title>
	<atom:link href="http://www.thehotaisle.com/2009/12/11/how-do-you-currently-choose-where-to-place-equipment-in-your-data-centre/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.thehotaisle.com/2009/12/11/how-do-you-currently-choose-where-to-place-equipment-in-your-data-centre/</link>
	<description>Fresh Thinking on IT Operations</description>
	<lastBuildDate>Mon, 26 Jul 2010 20:42:19 +0000</lastBuildDate>
	<generator>http://wordpress.org/?v=2.9.2</generator>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
		<item>
		<title>By: Michael Rowan</title>
		<link>http://www.thehotaisle.com/2009/12/11/how-do-you-currently-choose-where-to-place-equipment-in-your-data-centre/comment-page-1/#comment-7263</link>
		<dc:creator>Michael Rowan</dc:creator>
		<pubDate>Tue, 26 Jan 2010 14:10:50 +0000</pubDate>
		<guid isPermaLink="false">http://www.thehotaisle.com/?p=1792#comment-7263</guid>
		<description>Steve, 

I was watching this poll back in November/December but missed your comments.  

We have seen the same thing in our customers as your survey shows.  What&#039;s interesting here is the power draw and heat in todays servers are so directly tied to utilization, which is low in most places, but variable over time -- some servers can double or more power consumption as a result of increased utilization!  As a result, many IT managers are forced to place equipment by exaggerated specifications from vendors, instantaneous or average current draw (via rack PDU&#039;s or rack sensors), or by current temperature.  

The problem is that these are all just instantaneous readings and measurements, they don&#039;t account for the combination of what the average draw is for given equipment AND the potential draw of the same equipment.  So the rack that seems quite neat for a piece of equipment today can be a disaster tomorrow.   

We are coming at this from both sides -- using a top-down power monitoring of the actual IT equipment (servers, virtual servers, storage arrays, networks) and anchoring that monitoring with data from the physical infrastructure when available (rack PDU, BCM, etc).  It gives us the ability to see long term how equipment is drawing power (and what it&#039;s actual capabilities are based on configuration) as well as seeing how applications are responsible for that power draw (which can gets really interesting both in organizations that want to do real charge-back or are starting to embrace application mobility.  

There are a number of ways to skin the cat, but placement is a sophisticated task that requires consideration from more than just vendor faceplate, instant PDU readings, or how hot a rack seems.  (Of course, I&#039;ve been in a lot of data centers that just hunt for a open slot, so ... ;-)

Thanks for the data Steve.  Awesome stuff.</description>
		<content:encoded><![CDATA[<p>Steve, </p>
<p>I was watching this poll back in November/December but missed your comments.  </p>
<p>We have seen the same thing in our customers as your survey shows.  What&#8217;s interesting here is the power draw and heat in todays servers are so directly tied to utilization, which is low in most places, but variable over time &#8212; some servers can double or more power consumption as a result of increased utilization!  As a result, many IT managers are forced to place equipment by exaggerated specifications from vendors, instantaneous or average current draw (via rack PDU&#8217;s or rack sensors), or by current temperature.  </p>
<p>The problem is that these are all just instantaneous readings and measurements, they don&#8217;t account for the combination of what the average draw is for given equipment AND the potential draw of the same equipment.  So the rack that seems quite neat for a piece of equipment today can be a disaster tomorrow.   </p>
<p>We are coming at this from both sides &#8212; using a top-down power monitoring of the actual IT equipment (servers, virtual servers, storage arrays, networks) and anchoring that monitoring with data from the physical infrastructure when available (rack PDU, BCM, etc).  It gives us the ability to see long term how equipment is drawing power (and what it&#8217;s actual capabilities are based on configuration) as well as seeing how applications are responsible for that power draw (which can gets really interesting both in organizations that want to do real charge-back or are starting to embrace application mobility.  </p>
<p>There are a number of ways to skin the cat, but placement is a sophisticated task that requires consideration from more than just vendor faceplate, instant PDU readings, or how hot a rack seems.  (Of course, I&#8217;ve been in a lot of data centers that just hunt for a open slot, so &#8230; <img src='http://www.thehotaisle.com/wp-includes/images/smilies/icon_wink.gif' alt=';-)' class='wp-smiley' /> </p>
<p>Thanks for the data Steve.  Awesome stuff.</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: Pete Williams</title>
		<link>http://www.thehotaisle.com/2009/12/11/how-do-you-currently-choose-where-to-place-equipment-in-your-data-centre/comment-page-1/#comment-7221</link>
		<dc:creator>Pete Williams</dc:creator>
		<pubDate>Fri, 08 Jan 2010 01:37:05 +0000</pubDate>
		<guid isPermaLink="false">http://www.thehotaisle.com/?p=1792#comment-7221</guid>
		<description>Apologies for late comments on some of your blogs Steve, I&#039;m just catching up with your most recent ones.

I developed and implemented a tool while working under Steve (client will remain anonymous unless Steve is happy for me to say who, but they were quite a signifficant company) that helped give information to the Space Management Board for planning the rollout of new equipment.

It was integrated with the client CMDB and a 3rd party visualisation tool. 

It first took a feed of the whole client estate and the physical location of each device, from Site, Floor, Room, Tile, Rack to tin (including make &amp; model, and more importantly - Power Demand and Heat Output!), even application and service (will explain why later).

We then ran an audit of M&amp;E infrastructure on key data centres to establish linkages between transformers, UPS&#039;, PDU&#039;s, ACU&#039;s and the total capacity of each.

An audit was then ran to store which PDUs were attached to which tins.

Can you see where I&#039;m going with this?

After the pain of initial data collection, we were able to view the &#039;theoretical&#039; power demand on each PDU, UPS, Transformer, Room, Site, Cabinet and so on because we already knew the physical location, hence knowing the power utilisation of pretty much every M&amp;E device and their available capacity.

Not only did we know power availability and capacity, but we could highlight hot and cold spots.

The tool enabled the client to run all kinds of reports:

1) Where do we have &#039;physical space&#039;
2) Where do we have &#039;available power&#039;
3) Where do we have &#039;available cooling capacity&#039;
4) Where do we have dangerously high loading on either power or cooling?
5) Do we have any business critical applications which fall under and high risk spots
6) Do I have an kit which is currently only single or dual fed kit?
7) Do I have any business critical applications on kit which is only single fed??

The list was endless and gave the client and space management board an invaluable tool on which to make critical business decisions, aid planning, and reduce risk.

The one small flaw with this is that the power demand of kit was theoretical.  We got round this by factoring the manufacturers stated power consumption by 70%, which is more realistic, but not an exact science.

We did move one step further in this process towards the end of my time with said client, where we introduced iPDUs.  These gave a real time reading of power consumption at PDU level, and as long as we knew the relationship between tin and iPDU, we could provide even more accurante reports for the client where the iPDUs had been introduced.</description>
		<content:encoded><![CDATA[<p>Apologies for late comments on some of your blogs Steve, I&#8217;m just catching up with your most recent ones.</p>
<p>I developed and implemented a tool while working under Steve (client will remain anonymous unless Steve is happy for me to say who, but they were quite a signifficant company) that helped give information to the Space Management Board for planning the rollout of new equipment.</p>
<p>It was integrated with the client CMDB and a 3rd party visualisation tool. </p>
<p>It first took a feed of the whole client estate and the physical location of each device, from Site, Floor, Room, Tile, Rack to tin (including make &amp; model, and more importantly &#8211; Power Demand and Heat Output!), even application and service (will explain why later).</p>
<p>We then ran an audit of M&amp;E infrastructure on key data centres to establish linkages between transformers, UPS&#8217;, PDU&#8217;s, ACU&#8217;s and the total capacity of each.</p>
<p>An audit was then ran to store which PDUs were attached to which tins.</p>
<p>Can you see where I&#8217;m going with this?</p>
<p>After the pain of initial data collection, we were able to view the &#8216;theoretical&#8217; power demand on each PDU, UPS, Transformer, Room, Site, Cabinet and so on because we already knew the physical location, hence knowing the power utilisation of pretty much every M&amp;E device and their available capacity.</p>
<p>Not only did we know power availability and capacity, but we could highlight hot and cold spots.</p>
<p>The tool enabled the client to run all kinds of reports:</p>
<p>1) Where do we have &#8216;physical space&#8217;<br />
2) Where do we have &#8216;available power&#8217;<br />
3) Where do we have &#8216;available cooling capacity&#8217;<br />
4) Where do we have dangerously high loading on either power or cooling?<br />
5) Do we have any business critical applications which fall under and high risk spots<br />
6) Do I have an kit which is currently only single or dual fed kit?<br />
7) Do I have any business critical applications on kit which is only single fed??</p>
<p>The list was endless and gave the client and space management board an invaluable tool on which to make critical business decisions, aid planning, and reduce risk.</p>
<p>The one small flaw with this is that the power demand of kit was theoretical.  We got round this by factoring the manufacturers stated power consumption by 70%, which is more realistic, but not an exact science.</p>
<p>We did move one step further in this process towards the end of my time with said client, where we introduced iPDUs.  These gave a real time reading of power consumption at PDU level, and as long as we knew the relationship between tin and iPDU, we could provide even more accurante reports for the client where the iPDUs had been introduced.</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: Everett Thompson</title>
		<link>http://www.thehotaisle.com/2009/12/11/how-do-you-currently-choose-where-to-place-equipment-in-your-data-centre/comment-page-1/#comment-7100</link>
		<dc:creator>Everett Thompson</dc:creator>
		<pubDate>Fri, 18 Dec 2009 19:24:10 +0000</pubDate>
		<guid isPermaLink="false">http://www.thehotaisle.com/?p=1792#comment-7100</guid>
		<description>Excellent input.  We&#039;ve seen some decent tools lately, but they&#039;ve been too expensive...we are still looking.  Toda, we build custom spreadsheets for our clients.

Best,

Everett</description>
		<content:encoded><![CDATA[<p>Excellent input.  We&#8217;ve seen some decent tools lately, but they&#8217;ve been too expensive&#8230;we are still looking.  Toda, we build custom spreadsheets for our clients.</p>
<p>Best,</p>
<p>Everett</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: Steve O'Donnell</title>
		<link>http://www.thehotaisle.com/2009/12/11/how-do-you-currently-choose-where-to-place-equipment-in-your-data-centre/comment-page-1/#comment-7093</link>
		<dc:creator>Steve O'Donnell</dc:creator>
		<pubDate>Fri, 11 Dec 2009 20:01:23 +0000</pubDate>
		<guid isPermaLink="false">http://www.thehotaisle.com/?p=1792#comment-7093</guid>
		<description>Thanks Philip

This is a very important issue. For Enterprises there is a conflict between data center efficiency - fitting it all in - and reliability. Getting the balance right without tooling is actually impossible. 

Organizations that push the boundaries too far risk a catastrophic failure that could take days to unravel (burned out PDUs and Bus Bars). Organisations that don&#039;t fit everything in won&#039;t maximize their capital efficiency.

Anyone else seen any good solutions?

Steve</description>
		<content:encoded><![CDATA[<p>Thanks Philip</p>
<p>This is a very important issue. For Enterprises there is a conflict between data center efficiency &#8211; fitting it all in &#8211; and reliability. Getting the balance right without tooling is actually impossible. </p>
<p>Organizations that push the boundaries too far risk a catastrophic failure that could take days to unravel (burned out PDUs and Bus Bars). Organisations that don&#8217;t fit everything in won&#8217;t maximize their capital efficiency.</p>
<p>Anyone else seen any good solutions?</p>
<p>Steve</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: Philip</title>
		<link>http://www.thehotaisle.com/2009/12/11/how-do-you-currently-choose-where-to-place-equipment-in-your-data-centre/comment-page-1/#comment-7092</link>
		<dc:creator>Philip</dc:creator>
		<pubDate>Fri, 11 Dec 2009 19:27:10 +0000</pubDate>
		<guid isPermaLink="false">http://www.thehotaisle.com/?p=1792#comment-7092</guid>
		<description>Steve,

If I have understood things from the poll correctly, the picture is that most organisations do not have any form of real-time monitoring of where the power is going, particularly down to the rack level, and limited visibility of temperature.

I believe that discussions we are having with data centre managers complement your findings.  They tell us that real-time monitoring of power and environmentals down to the rack level  is becoming critical to managing:
- service reliability and quality
- capacity
- cost

Yet they are struggling to find affordable, usable tools to help them do this.  Typically, they are taking intermittent, irregular manual readings from a few meters.  This tells them little.

Our InSite software product addresses this by:
- monitoring any IP-addressable, metered power strips, environmental sensors, main PDU meters, UPS etc
- dashboarding information onto floorplans, schematics etc with real-time feeds to icons
- providing interactive, real-time reporting
- taking automated actions, including alerts on threshold breaches.

If any of your readers are interested in discussing this subject further to see if we can help them, I would be delighted to hear from them.

Thanks,
Philip</description>
		<content:encoded><![CDATA[<p>Steve,</p>
<p>If I have understood things from the poll correctly, the picture is that most organisations do not have any form of real-time monitoring of where the power is going, particularly down to the rack level, and limited visibility of temperature.</p>
<p>I believe that discussions we are having with data centre managers complement your findings.  They tell us that real-time monitoring of power and environmentals down to the rack level  is becoming critical to managing:<br />
- service reliability and quality<br />
- capacity<br />
- cost</p>
<p>Yet they are struggling to find affordable, usable tools to help them do this.  Typically, they are taking intermittent, irregular manual readings from a few meters.  This tells them little.</p>
<p>Our InSite software product addresses this by:<br />
- monitoring any IP-addressable, metered power strips, environmental sensors, main PDU meters, UPS etc<br />
- dashboarding information onto floorplans, schematics etc with real-time feeds to icons<br />
- providing interactive, real-time reporting<br />
- taking automated actions, including alerts on threshold breaches.</p>
<p>If any of your readers are interested in discussing this subject further to see if we can help them, I would be delighted to hear from them.</p>
<p>Thanks,<br />
Philip</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: Steve O'Donnell</title>
		<link>http://www.thehotaisle.com/2009/12/11/how-do-you-currently-choose-where-to-place-equipment-in-your-data-centre/comment-page-1/#comment-7091</link>
		<dc:creator>Steve O'Donnell</dc:creator>
		<pubDate>Fri, 11 Dec 2009 18:43:48 +0000</pubDate>
		<guid isPermaLink="false">http://www.thehotaisle.com/?p=1792#comment-7091</guid>
		<description>Philip,

The Hot Aisle polls are unsophisticated. They prevent the same person voting more than once but don&#039;t record location. Tell us how you resolve the problems in the article?

Steve</description>
		<content:encoded><![CDATA[<p>Philip,</p>
<p>The Hot Aisle polls are unsophisticated. They prevent the same person voting more than once but don&#8217;t record location. Tell us how you resolve the problems in the article?</p>
<p>Steve</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: Philip</title>
		<link>http://www.thehotaisle.com/2009/12/11/how-do-you-currently-choose-where-to-place-equipment-in-your-data-centre/comment-page-1/#comment-7090</link>
		<dc:creator>Philip</dc:creator>
		<pubDate>Fri, 11 Dec 2009 15:36:00 +0000</pubDate>
		<guid isPermaLink="false">http://www.thehotaisle.com/?p=1792#comment-7090</guid>
		<description>Steve,
This is very interesting data you have uncovered.  And, yes, I agree that there is a gap in the market (which is why my company is addressing it!)
Did you notice any geographic variations across your respondents or is this pretty much a consisten picture wherever the companies are located?
Thanks,
Philip</description>
		<content:encoded><![CDATA[<p>Steve,<br />
This is very interesting data you have uncovered.  And, yes, I agree that there is a gap in the market (which is why my company is addressing it!)<br />
Did you notice any geographic variations across your respondents or is this pretty much a consisten picture wherever the companies are located?<br />
Thanks,<br />
Philip</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: Tweets that mention Server placement survey uncovers cascade failure risk in Enterprise Data Centres &#124; The Hot Aisle -- Topsy.com</title>
		<link>http://www.thehotaisle.com/2009/12/11/how-do-you-currently-choose-where-to-place-equipment-in-your-data-centre/comment-page-1/#comment-7089</link>
		<dc:creator>Tweets that mention Server placement survey uncovers cascade failure risk in Enterprise Data Centres &#124; The Hot Aisle -- Topsy.com</dc:creator>
		<pubDate>Fri, 11 Dec 2009 15:28:57 +0000</pubDate>
		<guid isPermaLink="false">http://www.thehotaisle.com/?p=1792#comment-7089</guid>
		<description>[...] This post was mentioned on Twitter by Steve O&#039;Donnell, True Blood Sucker. True Blood Sucker said: Server placement survey uncovers cascade failure risk in ...: Previous: Not component optimization but solution opt... http://bit.ly/4KCX5d [...]</description>
		<content:encoded><![CDATA[<p>[...] This post was mentioned on Twitter by Steve O&#39;Donnell, True Blood Sucker. True Blood Sucker said: Server placement survey uncovers cascade failure risk in &#8230;: Previous: Not component optimization but solution opt&#8230; <a href="http://bit.ly/4KCX5d" rel="nofollow">http://bit.ly/4KCX5d</a> [...]</p>
]]></content:encoded>
	</item>
</channel>
</rss>