Our atmosphere (the air around us) is made up of gasses consisting of nitrogen (78%), oxygen (21%), carbon dioxide (0.3%) and water in the form of vapor (humidity). The amount of water in the atmosphere is measured as a Relative Humidity (RH)
Data Center air should contain the proper amount of water vapor to maximize the availability [...]
IT Infrastructure specialist Richardson Eyres recently issued a press release to help drum up some consulting business in the Retail market but make some generally applicable and interesting points worth looking at.
Even though most organizations are making energy cuts a top priority for 2008/9, many are not taking green issues seriously enough and are adopting a do-it-yourself [...]
AVIVA (aka Norwich Union) is set to open its third data centre - Data Centre 3 (DC3) at the Broadlands Business Park near Norwich, UK this September. Although the site uses some modern design principles to minimize energy use, AVIVA have been far too conservative with the design and the opportunity to really go green has been missed.
The site [...]
The photograph shows what happens when cable management is left to chance. The weight of the cables will put strain on the connections resulting in unexpected failures. Almost certainly the mess will grow and the jumble of cables will spill out of the rack door causing a trip hazard.
Yeugh!
This picture comes from Craig Black and shows the most artistic cable management setup I have ever seen. Incredibly tidy and neat.
Craig comments that
“The horizontal stuff is Leviton and the vertical is Panduit. It all came together really well — we wanted to make it look neat and it ended up that way.”
This is an essential piece of equipment in a data center. A device designed to lift and hold servers and other rack mounted equipment ready to install into their home rack.
Without one of these (or something similar), it is just a matter of time before you drop a server and injure yourself or a colleague. [...]
A photograph from the BT Rochdale Data Center showing how the transparent curtains are attached to the roof. These curtains are used to separate the Hot Aisle from the Cold Aisle in order to drive up cooling capacity and efficiency. There are a number of articles about using Curtains to drive energy efficiency on The [...]
Continue ReadingThis is an interesting photograph of a commercially available APC Hot Aisle containment system. With adequate cold air to our raised floor, this rack module can house high density equipment.
Continue ReadingHVAC Economizers (sometimes known as air-side Economizers) are useful for data centers which are located in regions of the world where the outdoor temperature is lower than the desired data center temperature (for at least some of the day or year) and the outdoor humidity is mild. Economizers save energy by cooling buildings with outside [...]
Continue Reading
This picture is from a BT Data Center in Holland, just outside Amsterdam.
There are quite significant airflow benefits to keeping power and data cables overhead and out of the plenum space under the floor. Underfloor pressures can be maximized and airflow design can be maintained.
If we can avoid lifting floor tiles when installing network and [...]
Dry coolers are used in many air cooled refrigeration systems. In case of low outdoor temperatures, outdoor air can be applied for cooling applications. In dry coolers, large fans create a forced airflow along air-to-water heat exchangers. Subsequently, the water circuit can be used for cooling of data centers, office buildings and industrial processes.
Dry coolers play an important role in [...]
This is a picture of the corridor around the I.Net Data Center in Milan showing much of the M&E equipment that is normally housed within the data center hall located outside.
So what are the benefits? Equipment can be maintained, filters changed etc.. without entering the raised floor area. Any heat load from the equipment is [...]
When was the last time you saw a Data Center press release that didn’t make some green or energy efficiency claim? I guess because data centers are such huge energy hogs vendors must worry that building a new one will raise the hackles of the environmentalists. Nevertheless PR agencies should really stop dressing up stories [...]
Continue ReadingIt’s not a new phenomenon, Sun did it over a decade ago with the 4500 range of servers that vent hot air left to right rather than front to back but it doesn’t make it any easier to run a complex site when major vendors like Cisco continue to insist on breaking the front to back [...]
Continue ReadingOne of the things that prompted me to write about CHP and Biomass was an email I received from a colleague, Howard Pheby of 5 nines. Howard, and his partner Paul Foskett, are announcing their plans to build a new data center complex co-located with a Biomass Plant just up the road from my home [...]
Continue ReadingIf, like most of us, you use a diesel generator as a backup power source during electrical outages, you need to understand something about Data Center engines and how to keep them running sweetly, starting automatically and reliably. It is horribly career limiting to spend your shareholders money on some equipment that you only need once every [...]
Continue ReadingI have had a great interchange from a subscriber to The Hot Aisle:- Darek Wichniewicz of ATM SA in Warsaw, Poland. Darek is looking for some real technical advice on building a new Data Center facility of 2000 - 3000 square meters utilizing fresh air cooling. Like many Data Center operators Darek is concerned about being [...]
Continue ReadingFloor loading is a badly understood issue in Data Centers. Not just in the place where the equipment eventually ends up but also en-route from the loading bay to the final resting place.
OK, so lets start looking at the problem. Most data centers have a raised floor made of specialist tiles held up on struts and a [...]
Continue ReadingHow did we get to the modern data centre design? Why do most data centres look the same? Why are they so inefficient in how they consume electrical power? Why do they typically have a raised plenum floor and air handling units that keep air at fixed temperature ranges and humidity levels?
I guess the first [...]