Dry coolers are used in many air cooled refrigeration systems. In case of low outdoor temperatures, outdoor air can be applied for cooling applications. In dry coolers, large fans create a forced airflow along air-to-water heat exchangers. Subsequently, the water circuit can be used for cooling of data centers, office buildings and industrial processes. Dry coolers play an important [...]
Continue ReadingThis is a picture of the corridor around the I.Net Data Center in Milan showing much of the M&E equipment that is normally housed within the data center hall located outside. So what are the benefits? Equipment can be maintained, filters changed etc.. without entering the raised floor area. Any heat load from the equipment [...]
Continue ReadingWhen was the last time you saw a Data Center press release that didn’t make some green or energy efficiency claim? I guess because data centers are such huge energy hogs vendors must worry that building a new one will raise the hackles of the environmentalists. Nevertheless PR agencies should really stop dressing up stories [...]
Continue ReadingIt’s not a new phenomenon, Sun did it over a decade ago with the 4500 range of servers that vent hot air left to right rather than front to back but it doesn’t make it any easier to run a complex site when major vendors like Cisco continue to insist on breaking the front to back [...]
Continue ReadingOne of the things that prompted me to write about CHP and Biomass was an email I received from a colleague, Howard Pheby of 5 nines. Howard, and his partner Paul Foskett, are announcing their plans to build a new data center complex co-located with a Biomass Plant just up the road from my home [...]
Continue ReadingIf, like most of us, you use a diesel generator as a backup power source during electrical outages, you need to understand something about Data Center engines and how to keep them running sweetly, starting automatically and reliably. It is horribly career limiting to spend your shareholders money on some equipment that you only need once every [...]
Continue ReadingI have had a great interchange from a subscriber to The Hot Aisle:- Darek Wichniewicz of ATM SA in Warsaw, Poland. Darek is looking for some real technical advice on building a new Data Center facility of 2000 – 3000 square meters utilizing fresh air cooling. Like many Data Center operators Darek is concerned about being [...]
Continue ReadingFloor loading is a badly understood issue in Data Centers. Not just in the place where the equipment eventually ends up but also en-route from the loading bay to the final resting place. OK, so lets start looking at the problem. Most data centers have a raised floor made of specialist tiles held up on struts and [...]
Continue ReadingHow did we get to the modern data centre design? Why do most data centres look the same? Why are they so inefficient in how they consume electrical power? Why do they typically have a raised plenum floor and air handling units that keep air at fixed temperature ranges and humidity levels? I guess the [...]